TruSeq Custom Amplicon Kit Dx

A validated, FDA-regulated kit enabling clinical laboratories to design their own next-generation sequencing assays for use on the MiSeqDx and NextSeq 550Dx systems. Read More...

This product is only available in select locations. Please select the location where you would like this product to be shipped to see availability.

Select Product(s)

TruSeq® Custom Amplicon Kit Dx

20005718

Price
 
 
Sold Separately
What materials do I need?

TruSeq® Custom Amplicon Dx – FFPE QC

20006259

Price
 
 

TruSeq Index Plate Fixture Kit (2 fixtures)

FC-130-1005

Price
 
 

TruSeq Index Plate Fixture & Collar Kit (2 each)

FC-130-1007

Price
 
 

MiSeq Dx Reagent Kit v3

20037124

Price
 
 

NextSeq550Dx Reagent Kit v2(300 cyc) IVD

20019554

NextSeq 550Dx High Output Reagent Kit v2.5 (300 cycles) IVD

20028871

Price
 
 

The TruSeq Custom Amplicon Kit Dx is an FDA-regulated amplicon sequencing kit that enables clinical labs to develop their own next-generation sequencing (NGS) assays for use on the FDA-regulated MiSeqDx and NextSeq 550Dx instruments.

  • Flexible assay design – Developed to meet individual, customer-defined needs
  • Validated kit – Verified performance specifications when used with Illumina instruments and reagents
  • Fast, reproducible results – Consistent results between multiple operators and systems
Flexible Assay Design

With the TruSeq Custom Amplicon Kit Dx, molecular diagnostics labs develop assays using their own oligonucleotide probe designs. The kit is optimized for use with formalin-fixed, paraffin-embedded (FFPE) samples and whole blood. This flexibility enables labs to expand the number of applications they can provide to meet customer needs.

Validated Kit

The TruSeq Custom Amplicon Kit Dx is validated to ensure consistent performance between lots, enabling long-term assay use, and facilitating change management.

High Assay Reproducibility

As demonstrated by a precision study, data produced using the TruSeq Custom Amplicon Kit Dx are highly reproducible.* Together with the MiSeqDx or NextSeq 550Dx, the TruSeq Custom Amplicon Kit Dx offers the accuracy and reliability needed to bring NGS capabilities into the clinical laboratory.

*See supporting data below

Frequently Purchased Together

Specifications

TruSeq Custom Amplicon Kit Dx

The Illumina TruSeq Custom Amplicon Kit Dx is a set of reagents and consumables used to prepare sample libraries from DNA extracted from peripheral whole blood and formalin-fixed, paraffin-embedded (FFPE) tissue. User-supplied analyte specific reagents are required for the preparation of libraries targeting specific genomic regions of interest. The generated sample libraries are intended for use on Illumina's high-throughput DNA sequence analyzers.

TruSeq Custom Amplicon Dx – FFPE QC Kit

The Illumina TruSeq Custom Amplicon Dx – FFPE QC Kit is a set of reagents used to determine the amplification potential of genomic DNA (gDNA) extracted from formalin-fixed, paraffin-embedded (FFPE) samples.

MiSeqDx Reagent Kit v3

The Illumina MiSeqDx Reagent Kit v3 is a set of reagents and consumables intended for sequencing of sample libraries when used with validated assays. The MiSeqDx Reagent Kit v3 is intended for use with the MiSeqDx instrument and analytical software.

MiSeqDx Instrument

The MiSeqDx instrument is intended for targeted sequencing of DNA libraries from human genomic DNA extracted from peripheral whole blood or formalin-fixed, paraffin-embedded (FFPE) tissue, when used for in vitro diagnostic (IVD) assays performed on the instrument. The MiSeqDx instrument is not intended for whole genome or de novo sequencing. The MiSeqDx instrument is to be used with registered and listed, cleared, or approved IVD reagents and analytical software.

NextSeq 550Dx Instrument (United States)

The NextSeq 550Dx instrument is intended for targeted sequencing of DNA libraries from human genomic DNA extracted from peripheral whole blood or formalin-fixed, paraffin-embedded (FFPE) tissue, when used for in vitro diagnostic (IVD) assays performed on the instrument. The NextSeq 550Dx instrument is not intended for whole genome or de novo sequencing. The NextSeq 550Dx instrument is to be used with registered and listed, cleared or approved, IVD reagents and analytical software.

NextSeq 550Dx Instrument (European Union)

The NextSeq 550Dx instrument is intended for sequencing of DNA libraries when used with in vitro diagnostic (IVD) assays performed on the instrument. The NextSeq 550Dx instrument is to be used with specific registered, certified or approved IVD reagents and analytical software.

NextSeq 550Dx High-Output Reagent Kit v2 (300 cycles)

The Illumina NextSeq 550Dx High-Output Reagent Kit v2 (300 cycle) is a set of reagents and consumables intended for sequencing of sample libraries when used with validated assays. The kit is intended for use with the NextSeq 550Dx instrument and analytical software.

NextSeq 550Dx High Output Reagent Kit v2.5 (300 cycles)

The Illumina NextSeq 550Dx High Output Reagent Kit v2.5 (300 cycles) is a set of reagents and consumables intended for sequencing of sample libraries when used with validated assays. The kit is intended for use with the NextSeq 550Dx instrument and analytical software.

Method-Specific Workflow Example

 

Supporting Data and Figures

 

The TruSeq Custom Amplicon Kit Dx is the recommended replacement product for the MiSeqDx Universal Kit, which has been discontinued. Illumina remains committed to providing you with high-quality support and service.

Related Products

AmpliSeq for Illumina Custom RNA Panel

Targeted, custom RNA research panels optimized for sequencing up to 1200 genomic targets of interest.


AmpliSeq for Illumina Custom DNA Panel

Targeted custom research panels optimized for sequencing specific targets or genomic content of interest.


TruSight Cystic Fibrosis

FDA-regulated, CE-IVD-marked next-generation sequencing test that conveniently provides two cystic fibrosis testing assays in one product.